      偏光热台 → BX41-P  
 
An extensive range of compensators is
available

Six different compensators, tint plate and
1/4 wavelength retardation plate are
available for the BX41-P microscope,
allowing measurement of various retardation
levels, ranging from 0 to 20λ. For easier
measurement, the direct readout method is
featured. Higher image contrast can be
attained by using a Senarmont* or Brace-
Koehler compensator to change the
retardation level in the entire field of view.
* Used with monochromatic green filter, IF546 or IF550.
              << 第一页 上一页 >>




Measuring range of compensators
Compensator Measurement range Applications
Thick Berek (U-CTB) 0-11,000nm (20λ) Measurement of high retardation level (R*>3λ),(crystals, macromolecules, fiber, etc.)
Berek (U-CBE) 0-1,640nm (3λ) Measurement of retardation level
(crystals, macromolecules, living organisms, etc.)
Senarmont compensator(U-CBE) 0-546nm (1λ) Measurement of retardation level (crystals, living organisms, etc.)
Enhancement of image contrast (living organisms, etc.)
Brace-Koehler compensator
1/10λ (U-CBR1)
0-55nm (1/10λ) Measurement of low retardation level (living organisms, etc.)
Brace-Koehler compensator
1/30λ (U-CBE2)
0-20nm (1/30λ) Enhancement of image contrast (living organisms, etc.)
Quartz wedge (U-CWE2) 500-2,200nm (4λ) Approximate measurement of retardation level(crystal, macromolecules, etc.)
 
Unmatched sharpness in orthoscopic
and conoscopic observations
With a U-CPA conoscopic observation
attachment, changeover between
orthoscopic and conoscopic observation is
simple and quick. Focusing of conoscopic
images is easy and accurate. Employing a
Bertrand field stop makes it possible to
obtain consistently sharp and clear
conoscopic images.
 
An upgrade in polarization characteristics
ACHN-P strain-free objectives reduce
internal strain to an absolute minimum.
Olympus has also totally redesigned its
polarizers and polarizing condensers to
further enhance performance in polarized
  light. This means a higher EF* value,
resulting in unmatched image contrast.
*The EF (extinction factor) is the brightness ratio
between parallel and crossed pol-filters.
The higher the EF value, the better the extinction.

PLN-P Series
Item N.A. W.D.
PLN 4XP 0.1 18.5mm

ACHN-P Series
Item N.A. W.D.
ACHN 10XP 0.25 6.0mm
ACHN 20XP 0.40 3.0mm
ACHN 40XP 0.65 0.45mm
ACHN 100XOP 1.25 0.13mm
 
Easy, accurate gout inspection
A transmitted light gout analyzer (U-GAN)
and rotatable stage (U-SRG2) are provided
for easy, accurate gout detection.
Simple pol option
With the use of U-SC3 swing out condenser,
U-POT polarizer and U-ANT analyzer for
transmitted light, it is possible to get optimal
polarizing images from 1.25X to 100X.
 
Corresponds to reflected light
observation
Reflected light illuminator and polarizing
equipment can be attached simultaneously.
BX-RLA2 complies with 100W halogen
illumination and BX-KMA accepts 30W
halogen illumination, both provides high
intensity and long lifetime.
Cross-movement mechanical stage
Mounting an attachable cross-movement
mechanical stage (U-FMP) onto the circular
rotatable stage makes for improved
observation efficiency. Interference between
the mechanical stage and the objectives is
eliminated, so that images of superb quality
can be effortlessly observed with all objective
magnification.
 